Livonia Metal Roofing logo
Red-brick ranch house with a new charcoal standing seam metal roof and snow guard clips along the eave, autumn trees behind

Commercial Metal Roofing in Livonia

Livonia Metal Roofing takes requests for commercial metal roofing: structural standing seam over open purlins, metal-over-metal retrofit framing, insulated metal roof panels, architectural panels on mansards and canopies, and repair and recoating of older panel roofs. Commercial work runs to a written spec, and the first questions are the roof's slope, its purlin spacing and whether the old roof stays in place. For a commercial roof, the independent contractor we refer surveys the building and prices the system against that spec.

Get a free metal roofing estimate

Free for homeowners. One local contractor contacts you.

Commercial Metal Roofing Systems

Long grey structural standing seam panels running over a low-slope warehouse roof with mechanically seamed ribs

Structural Standing Seam over Purlins

Structural standing seam is the usual metal roof for low-slope warehouses, light-industrial buildings and big-box retail. The panels are mechanically seamed, and once seamed they can span open purlins up to about five feet apart and carry load on their own, without a deck underneath. A non-curing butyl sealant in the seam keeps water out where it sits longer. Structural panels can go on slopes from 1/2:12 all the way to a vertical wall.

Panel maker DMI's rule of thumb is simple: below 3:12, or wherever panels span open purlins, the job needs a structural panel. Long runs on big roofs need clips that let the panels slide as they heat and cool, which our standing seam metal roofing page explains. Wind uplift ratings for these systems come from UL 580 or ASTM E1592 testing of the full assembly, so the spec should name one.

Light-gauge steel sub-framing installed over an old ribbed metal roof, with new standing seam panels on part of it

Metal-over-Metal Retrofit Framing

When an old exposed-fastener roof is past saving, it usually doesn't have to come off. Retrofit systems fasten light-gauge steel sub-framing through to the building's structure, over the existing roof, and the new metal roof goes on that framing. The old panels stay in place, and the building doesn't have to be opened up while people work inside.

The same approach turns a flat or nearly flat built-up roof into a sloped metal one. The space between the old roof and the new one can take added insulation or ventilation, and the new system is designed to current wind and gravity load requirements.

Weight is the check. A metal-over-metal retrofit adds about 1.5 to 2.5 pounds per square foot, according to an IIBEC article on retrofit purlins, and a professional should confirm the existing supports can take it, especially with rooftop units, solar or heavy snow in the picture.

Insulated Metal Roof Panels

Insulated metal panels (IMPs) are a rigid foam core bonded between metal faces, so the roof and its insulation go on in one piece. They suit buildings where the roof has to carry a lot of insulation and the owner wants it in a single layer.

The R-value depends on the core and its thickness. Kingspan gives about R-5 to R-7.1 per inch for polyurethane (PUR) cores and R-7 to R-7.2 per inch for polyisocyanurate (PIR). Mineral fiber cores, which run about R-3.6 to R-4.2 per inch, get used where the fire spec calls for them.

Architectural Panels for Mansards and Canopies

Architectural panels are the steep-slope standing seam you see on mansards, entry towers, canopies and the sloped fascia of strip centers and office buildings. They need a solid substrate behind them (plywood, metal deck, polyiso board or an existing roof) and are meant for slopes above 3:12, where water runs off before it can back up into a snap seam.

The reason is winter. When snow or an ice dam sits at an eave or in a valley and the sun starts a thaw, meltwater can creep uphill into a snap-together seam by capillary action, and butyl sealant alone may not hold it. Where a mansard ends at a gutter or a flat roof, the transition detail is worth a close look on the drawings. Coping, fascia and edge trim on flat-roofed buildings are covered on our flashing and trim page.

Commercial Metal Roof Repair and Recoating

Plenty of older panel roofs on industrial and commercial buildings need maintenance rather than replacement: new fasteners with fresh washers, resealed laps and end laps, and repaired flashing at curbs and penetrations. That work is the same as on a house, only at scale; see metal roof repair. Where the paint has chalked and surface rust has spread across sound panels, a silicone or acrylic coating system over cleaned, rust-treated and re-fastened panels can buy years before a retrofit. Coating types and how long a recoat adds are on our metal roof coating page.

Gloved hands closing a standing seam between two grey steel panels with a hand seamer

Why Livonia homeowners call Livonia Metal Roofing

  • Estimate in writing, at no cost
  • Gauge, panel profile and paint finish named in the quote
  • Re-roof permit listed in the written scope
  • One independent local metal roofer per request
  • Homeowners pay nothing for the referral

Get a free metal roofing estimate

Free for homeowners. One local contractor contacts you.

What Shapes a Commercial Metal Roof Bid

Commercial metal roofs are priced against a spec, not a per-square-foot average. The lines that move a bid:

  • Slope and support

    Structural panels over purlins, or architectural panels over a deck.
  • Tear-off or retrofit

    Removing an old roof means disposal and exposure to weather, while retrofit framing adds steel and engineering.
  • Insulation

    Board insulation under the panels, or insulated panels, sized to the energy code.
  • Uplift and fire ratings

    A tested assembly under UL 580 or ASTM E1592, and a Class A fire rating where the code requires it.
  • Gauge and finish

    The gauge and a PVDF or SMP paint system, explained on our standing seam page.
  • Access and phasing

    Crane time, work around occupied space, and sequencing across buildings on a campus or an HOA property.

How a Commercial Project Runs

Livonia Metal Roofing connects you with one independent local contractor, who surveys, bids and builds the roof; we don't do the work ourselves.

  1. 1

    Roof survey

    The contractor checks the existing roof, the deck or purlins, drains, curbs and rooftop equipment, and flags wet insulation or rusted-through panels.
  2. 2

    System and spec

    Structural or architectural, retrofit or tear-off, insulation, and the tested assemblies that meet uplift and fire requirements. Retrofit framing and added loads get an engineer's check.
  3. 3

    Permit

    The City of Livonia says a building permit is generally needed to alter or repair a building or other structure, which covers commercial roofs as well as houses. The permit process for re-roofs is outlined on our metal roof replacement page.
  4. 4

    Install in phases

    Panels go on in sections that can be closed up at the end of each day, with flashing at curbs and penetrations done as each section closes.
  5. 5

    Closeout

    Final inspection, and the panel, finish and assembly documents handed over for the building file.

Things to Know Before You Bid It

  • Commercial code is the building code

    Commercial roofs fall under the Michigan Building Code, and the state lists the 2021 edition as current, effective April 9, 2025. Houses still follow the 2015 residential code.
  • Snow sits on low-slope roofs

    Parapets, rooftop units and lower roofs next to taller walls collect drifts; the area's snowfall and ground snow load are on our snow guards page.
  • Low slope has its own rules

    Minimum pitches for each panel type are on our low-slope metal roofing page.

Frequently asked questions

What's the difference between structural and architectural metal roof panels?

Structural panels are mechanically seamed and strong enough to span open purlins, up to about five feet apart, and they're used on slopes below 3:12. Architectural panels need a solid deck underneath, such as plywood, metal deck or insulation board, and are meant for slopes above 3:12, where water runs off quickly.

Can a new metal roof go over an old metal roof?

Often, yes. Retrofit systems set light-gauge steel framing over the existing roof's structure, so the old panels can usually stay in place and the building stays in use. A metal-over-metal retrofit adds about 1.5 to 2.5 pounds per square foot, so the existing purlins and frame should be checked before the design is final.

Can a flat commercial roof be converted to a metal roof?

Yes. Retrofit framing can build a new sloped plane over an existing flat or nearly flat roof, and a standing seam roof goes on top. The space between the old and new roof can take extra insulation or ventilation. The framing is engineered for current wind and gravity loads, so expect an engineer's involvement.

What R-value do insulated metal roof panels have?

It depends on the foam core and its thickness. Kingspan, a panel maker, gives about R-5 to R-7.1 per inch for polyurethane (PUR) cores and R-7 to R-7.2 per inch for polyisocyanurate (PIR). Mineral fiber cores, used where fire specs call for them, run about R-3.6 to R-4.2 per inch.

Should an old commercial metal roof be recoated or replaced?

Recoat it if the panels are sound and the problems are chalky paint, surface rust and leaking fasteners. Replace or retrofit it if panels are rusted through over large areas or the structure underneath is in doubt. A roof survey decides it, and our metal roof coating page covers the coating systems.

Ready to get started in Livonia?

Request a free estimate